Coastal Custom Home

A custom home on the Big Sur coastline: a demanding marine environment, a jurisdiction with rigorous review, and an owner who wanted the systems designed once, correctly. The package paired a 25-sheet MEP/FP set with a full ACCA Manual J/S/D engineering report.

LocationBig Sur, CA
TypeSingle-Family (Custom)
DisciplinesE · FP · M · P
Sheets12
SoftwareAutoCAD · Wrightsoft
PE StampIn-house (TX / CA)

Sample sheets from this set

Redacted sample sheet E002 from the Coastal Custom Home set
E002 ELECTRICAL
Redacted sample sheet M103 from the Coastal Custom Home set
M103 MECHANICAL
Redacted sample sheet M201 from the Coastal Custom Home set
M201 MECHANICAL
Redacted sample sheet MJ01 P1 from the Coastal Custom Home set
MJ01 P1 CALC / REPORT
Redacted sample sheet MJ01 P2 from the Coastal Custom Home set
MJ01 P2 CALC / REPORT
Redacted sample sheet P201 from the Coastal Custom Home set
P201 PLUMBING
Redacted sample sheet Manual J/S/D Report · p.1 from the Coastal Custom Home set
Manual J/S/D Report · p.1 CALC / REPORT
Redacted sample sheet Manual J/S/D Report · p.2 from the Coastal Custom Home set
Manual J/S/D Report · p.2 CALC / REPORT
Redacted sample sheet Manual J/S/D Report · p.3 from the Coastal Custom Home set
Manual J/S/D Report · p.3 CALC / REPORT
Redacted sample sheet Manual J/S/D Report · p.4 from the Coastal Custom Home set
Manual J/S/D Report · p.4 CALC / REPORT
Redacted sample sheet Manual J/S/D Report · p.5 from the Coastal Custom Home set
Manual J/S/D Report · p.5 CALC / REPORT
Redacted sample sheet Manual J/S/D Report · p.6 from the Coastal Custom Home set
Manual J/S/D Report · p.6 CALC / REPORT

Electrical

A complete new electrical system — service, panel schedule, load calculation, and single-line diagram — plus lower- and upper-floor lighting plans with a specification-grade fixture schedule (dimming, VA, and catalog data for every type, down to 4″ color-preference downlights and wet-location wall packs). Exterior devices are WP/GFI rated for the coastal exposure.

Mechanical & load engineering

The Manual J calculation put the whole-house load at roughly 18.9 kBtuh heating, with cooling equipment selected at 0.84 RSM per Manual S — capacity that meets the load instead of doubling it, which matters on a tight coastal envelope. The Manual D duct design runs to a 1,200 CFM air handler through a documented 760 ft total effective length, with a supply/return branch detail table for every room and 5 kW electric backup. Room-by-room loads, component constructions, and building analysis are all in the report — the difference between a permit-ready submittal and a rule-of-thumb sizing letter.

Plumbing

Water supply, drainage, and gas plans coordinated with the architecture across both floors.

Fire protection

Residential sprinkler design notes to NFPA 13 — head placement centered in ceiling grids, escutcheon and finish coordination, hanger and support requirements, and the fill-and-test procedure — written to hand the fire authority exactly what it reviews.

A design-once package — MEP/FP plans plus the Manual J/S/D engineering that sizes equipment to the load — issued permit-ready for a demanding coastal jurisdiction.

Complete MEP permit set built to get approved.

Every mechanical, electrical, plumbing, and fire sheet your reviewer needs — a fixed quote in 24 business hours, first sets in as few as 5 working days, and city comments answered until your permit is issued.