Single-Family Residence — Full Package

A Florida single-family project carried from design through permit corrections — the complete residential paper trail: a 14-sheet MEP set, ACCA Manual J & S report, REScheck energy-compliance certificate, and a formal response to county plan-review comments.

LocationBoca Raton, FL
TypeSingle-Family
DisciplinesE · M · P
Sheets8
SoftwareAutoCAD · Wrightsoft
PE StampLicensed partner

Sample sheets from this set

Redacted sample sheet E-4.0 — Riser & Panel from the Single-Family Residence — Full Package set
E-4.0 — Riser & Panel ELECTRICAL
Redacted sample sheet M-0.0 — Mechanical Notes from the Single-Family Residence — Full Package set
M-0.0 — Mechanical Notes MECHANICAL
Redacted sample sheet M-1.0 — Mechanical Plan from the Single-Family Residence — Full Package set
M-1.0 — Mechanical Plan MECHANICAL
Redacted sample sheet M-3.0 — Manual J/S Compliance from the Single-Family Residence — Full Package set
M-3.0 — Manual J/S Compliance MECHANICAL
Redacted sample sheet P-2.0 — Plumbing from the Single-Family Residence — Full Package set
P-2.0 — Plumbing PLUMBING
Redacted sample sheet Manual J/S Report · p.1 from the Single-Family Residence — Full Package set
Manual J/S Report · p.1 CALC / REPORT
Redacted sample sheet Manual J/S Report · p.2 from the Single-Family Residence — Full Package set
Manual J/S Report · p.2 CALC / REPORT
Redacted sample sheet Manual J/S Report · p.3 from the Single-Family Residence — Full Package set
Manual J/S Report · p.3 CALC / REPORT

Mechanical

A 2.5-ton, 30,000 Btuh heat-pump system with a 1,000 CFM air handler, floor and roof mechanical plans, sidewall exhaust details, and a Manual J/S compliance summary sheet bound into the drawing set (M-3.0) — the jurisdiction sees the load math inside the permit set, not in a loose attachment.

Electrical

Lighting and power plans (GFCI/wet-location devices per NEC), panel schedule with load calculation and riser diagram (E-4.0) — service sized and documented with 3#3/0 AWG Cu feeders in 2″ EMT.

Plumbing

Water-supply and drainage plans with TMV-protected fixtures and full details.

Compliance & corrections

The REScheck report documents envelope compliance for the Florida energy code; when the county issued review comments, the response package resolved them — resubmittal-ready. That correction cycle, handled fast, is the difference between a permit and a stack of red ink.

Permit-ready and correction-ready: coordinated M/E/P, Manual J/S bound into the set, a passing REScheck, and a plan-review response that turned red ink into an approval.

Complete MEP permit set built to get approved.

Every mechanical, electrical, plumbing, and fire sheet your reviewer needs — a fixed quote in 24 business hours, first sets in as few as 5 working days, and city comments answered until your permit is issued.